Everyone hits a wall with bus servos at some point, usually the first time two servos share an ID or a ground wire comes loose. The good news: the servos talk back, so you can nearly always find the fault by asking them. This lesson collects the problems from the whole course in one place.
Before reading the table, run the scan program from lesson 5, then ask:
flowchart TB
A["Run the ID scan"] --> B{"Anything found?"}
B -->|"No"| C["Power, TX and RX, ground, jumpers on A"]
B -->|"Yes"| D{"The IDs you expect?"}
D -->|"No"| E["Duplicate or wrong IDs: one servo at a time"]
D -->|"Yes"| F["Check torque, limits and load"]
| Problem | Solution | Why |
|---|---|---|
| No servo answers | Check the 7.4V supply is on, TX goes to RX and RX to TX, and both jumpers are on A | A swapped pair, no power, or the wrong jumper all look like silence |
| Garbled data or random disconnects | Join the Pico GND and the driver board GND, and check the baud rate is 1,000,000 | UART signals need a common reference |
| Nothing moves when two servos are chained | Connect them one at a time and give each its own ID | Two servos on one ID collide |
| A servo reverts to ID 1 | Set the ID again, then power-cycle and scan | The change didn’t stick, and only a power cycle proves it did |
| One servo answers, the rest don’t | Look for duplicate IDs, then check the cable before the first missing servo | The chain is broken at that point, or two share an ID |
| Servo twitches or stalls | Use a supply that delivers enough current, and check for a mechanical jam | A moving servo draws far more current than an idle one |
| A joint gets hot | Reduce the load or use a higher-torque variant, and use the temperature check from lesson 8 | A servo working against its limit heats up |
None from a read |
Check the ID and the wiring, and test for None in your code |
The servo didn’t reply in time |
| Servo moves but not where I asked | Check speed, the position range and the limits |
Out-of-range targets are clamped or refused |
| Problem | Solution | Why |
|---|---|---|
buddy: clamped is printed |
Widen min_deg and max_deg in config.json |
Requests are limited to those values |
| A joint goes the wrong way | Flip its sign and recalibrate |
The servo is mounted the other way round |
| Positions are wrong after calibration | Rerun calibrate.py with the arm held exactly at home |
The offsets record whatever pose you held |
| Joints arrive at different times | Use move_all_sync instead of move_all |
Equal speeds over unequal distances |
inverse_kinematics returns None |
Check reach, and leave yaw as atan2(y, x) |
The target is out of range, or yaw disagrees with the base |
| The gripper ends up in the wrong place | Measure the arm and set L1 to L5 in kinematics.py |
The shipped lengths are placeholders |
| Web sliders don’t move the arm | Toggle torque on | Some servos ignore targets with torque off |
| The 3D viewer is blank | Give the phone internet access | The viewer’s script comes from a CDN |
| The Pico never joins Wi-Fi | Use Buddy-Setup and resend the credentials, then read the wifi: lines |
boot_network() falls back to the access point on failure |
speed and gentle acc give you time to reacthealth_check.py that scans IDs 1 to 6, reads each servo’s temperature and position, and prints one line per servo.Problem: I fixed the wiring, but still nothing answers. Solution: Power-cycle the servo supply, then rerun the scan. Why: A servo that browned out may need a clean restart before it talks.
Problem: The program hangs.
Solution: Press Ctrl-C and check any while loop that waits on a reading has a timeout.
Why: A loop waiting for a servo that never answers waits for ever.